SGR, EP, ECG and winks accompanying repeated presentation of 80 and 105 db tones have been registered. 80 db tone provokes the orienting reaction while 105 db tone-the defence reaction. The latter is characterized by prolonged habituation in a number of measured indices. Existence of a compensatory psychophysiological mechanism is suggested the activity of which is a direct function of the strength of the defence reaction.